AII GPR-3100 Oxygen Analyzer
Features
- Measurement range:
- 0-100%, plus suppressed zero ranges
- 50, 80, or 90-100%
- Barometric pressure & temperature compensation
- Stainless steel wetted parts
- Range Identification output
- 4-20mA, 0-1V and 0-5V outputs
- 2 off user configurable alarm relays
- Universal mains powered
$4,998.00 – $5,406.00
• North Butyl Glovebox Gloves have the highest resistance to permeation by gases and vapors.
• Butyl provides the highest permeation resistance to vapors and gases: as well as exceptional resistance to a broad range of toxic chemicals: making it the only suitable glove choice for many critical applications.
• Butyl also has a soft and flexible feel: even at low temperatures: which reduces hand fatigue and enhances worker comfort.
• Solvent based: multi-dip manufacturing process provides multiple layers of polymer (like a glove within a glove) which results in a glove of superior quality.Features & Benefits:• Glovebox operations in the nuclear: defense: pharmaceutical: biotech: semi-conductor and manufacturing industries.
• Particularly suited to applications involving highly toxic chemical hazards: such as chemical weapons.
Measurement range | 0-100%, plus suppressed zero ranges. 50, 80, or 90-100% |
Accuracy | < ±2% of selected range ±0.1% at constant conditions after calibration with 95-100% oxygen (GPR-3100) |
Response time | T90 < 13 seconds |
Recovery time | Not applicable |
Sensitivity (LDL) | 0.1% oxygen |
Linearity | < 0.5% of scale |
Sensor model | GPR-11-120-OP |
Sensor life at 25°C and 1 atm | 24 months in 100% oxygen |
Calibration interval | Typically: 1-3 months |
Inlet pressure | 248 bar g (3600psig) |
Flow rate (constant) | 0.5 – 1.0 Nl/min (1-2 SCFH) |
Gas connections | 1/4″ compression tube fittings |
Display | Graphical LCD 12.7 x 7cm (5 x 2.75”); resolution 0.01 |
Enclosure | Painted aluminum See individual mounting options for dimensions |
Compensation | Barometric pressure and temperature; Temperature controlled sample system and sensor (GPR-3100 only) |
Analog output | 4-20 mA isolated, 0-1V, and 0-5V |
Range ID | 1-5 V or 4-20mA, optional relay contacts |
Communications | Choose from RS485, RS232 or USB |
Alarms | Two user-adjustable alarm relays |
Operating temperature | GPR sensor: 5°C to 45ºC (41°F to 113°F) XLT sensor: -10°C to 45°C (14°F to 113°F) |
Power | Universal 100-240 V AC |