AII GPR-1500 Series Oxygen Analyzer


Features

  • General purpose or intrinsically safe (ATEX) models
  • Measuring range: 0-10, 0-100, 0-1000 ppm, 0-1%, (0-25%)
  • Accuracy: <2%
  • Fast recovery from exposure to air
  • Measure in pure CO2 with XLT sensor
  • Two alarms with GPR-1500A analyzer model
  • XLT oxygen sensor
  • Indoor or outdoor applications

$1,836.00$3,392.00

Compare
  • The AII GPR-1500 Series Oxygen Analyzer is a wall mounted unit with NEMA enclosure. This single channel oxygen meter can be used with flow-through O2 cells for in-line gas analysis in safe as well as hazardous areas where ATEX approval is needed. The low detection limit of 0.05ppm offers low oxygen measurement down to a range of 0 to 10 ppm.
  • Ideal for clean gas applications and when used with the XLT oxygen sensor type it allows measurement in pure carbon dioxide.
  • The Analytical Industries long-life oxygen sensors are maintenance-free sealed electrochemical cells that don’t need top up of electrolyte and can be exchanged in few minutes.
SKU: N/A Category:
GPR-1500 A GPR-1500 N GPR-1500 N ATEX
Measurement range 0-10, 0-100, 0-1000 ppm, 0-1%, (0-25%) 0-10, 0-100, 0-1000 ppm, 0-1%, (0-25%) 0-10, 0-100, 0-1000 ppm, 0-1%, (0-25%)
Accuracy < 2% of selected range at constant conditions < 2% of selected range at constant conditions < 2% of selected range at constant conditions
Response time T90 < 10 seconds T90 < 10 seconds T90 < 10 seconds
Sensitivity (LDL) 0.05 ppm 0.05 ppm 0.05 ppm
Linearity <1% of scale <1% of scale <1% of scale
Sensor model GPR-12-333  for inert gas streams GPR-12-333  for inert gas streams GPR-12-333  for inert gas streams
XLT-12-333 for gases containing > 0.5% CO2 XLT-12-333 for gases containing > 0.5% CO2 XLT-12-333 for gases containing > 0.5% CO2
Sensor life at 25ºC (77°F) and 1 atm 24 months in < 1000 ppm O2 24 months in < 1000 ppm O2 24 months in < 1000 ppm O2
Calibration interval 30 days 30 days 30 days
Inlet pressure 0.34-2 barg (5-30 psig) with atmospheric vent 0.34-2 barg (5-30 psig) with atmospheric vent 0.34-2 barg (5-30 psig) with atmospheric vent
Flow rate 0.5-1.0 Nl/m (1-2 SCFH) 0.5-1.0 Nl/m (1-2 SCFH) 0.5-1.0 Nl/m (1-2 SCFH)
Gas connections 1/8″ compression tube fittings 1/8″ compression tube fittings 1/8″ compression tube fittings
Wetted parts Stainless steel Stainless steel Stainless steel
Display Graphical LCD 7 x 3.5cm (2.75 x 1.375″); resolution 0.01 Graphical LCD 7 x 3.5cm (2.75 x 1.375″); resolution 0.01 Graphical LCD 7 x 3.5cm (2.75 x 1.375″); resolution 0.01
Enclosure Fiberglass NEMA 4X, 6.75 x 8.375 x 4.25“ Fiberglass NEMA 4X, 6.75 x 8.375 x 4.25“ Fiberglass NEMA 4X, 6.75 x 8.375 x 4.25″
Weight 3.6kg (8lbs) 3.6kg (8lbs) 3.6kg (8lbs)
Compensation Temperature compensated output Temperature compensated output Temperature
Signal output 4-20 mA or 1-5 V, optional Modbus 4-20 mA 4-20 mA
Alarms Two user configurable alarms No alarms No alarms
Operating temperature GPR sensor: 5°C to 45°C (41°F to 113°F)
XLT sensor: -10° to 45°C (14°F to 113°F)
GPR sensor: 5°C to 45°C (41°F to 113°F)
XLT sensor: -10° to 45°C (14°F to 113°F)
GPR sensor: 5°C to 45°C (41°F to 113°F)
XLT sensor: -10° to 45°C (14°F to 113°F)
Power 12-28 V DC non-loop or 110-220 VAC 12-28 V DC non-loop or 110-220 VAC 18-24 V DC
Area classification General purpose General purpose UL:         Class I, Division 1, Group C, D hazardous areas with external intrinsic safety barrier
ATEX:     II 2 G
Ex ia IIB T4 Gb
Tamb    -20°C to +50°C
Recovery time 30 seconds in air to < 10 ppm in < 1 hour on N2 purge 30 seconds in air to < 10 ppm in < 1 hour on N2 purge 30 seconds in air to < 10 ppm in < 1 hour on N2 purge